Roof Framing Plan
The following items must be shown, detailed and/or noted on the “roof framing plan”:

***Please Note:  Structural criteria for all load bearing framing members must consider: (1) bending, (2) shear and (3) deflection.

Must be drawn to scale and dimensioned.

Must match the “site plan” and “floor plan(s)” configuration.

Roof truss types (“girder”, “hip master”, etc.) keyed to roof framing plan.

***Please Note: Truss manufacturer’s stamped/signed truss layout plan and the individual engineered stamped/signed roof truss shop drawings will be required at the time of the “strap and shear” inspection. Both truss layout plan and truss shop drawing(s) must match theapproved roof framing plan.

Roof rafter sizing (section R802.5, I.R.C.).

***Please Note: In addition to sizing, lumber specie and grade must be noted.

Ceiling joist sizing (Table R802.4, I.R.C.).

***Please Note: In addition to sizing, lumber specie and grade must be noted.

Post, beam and header sizing.

***Please Note: In addition to sizing, lumber specie and grade must be noted.

Purlins, braces, bearing points, over-framing, etc, must be properly delieated on the plan.

All roof overhangs and lookout spacing must be shown and dimensioned.